• AI글쓰기 2.1 업데이트
PARTNER
검증된 파트너 제휴사 자료

현장 실험을 통한 주거용 열회수 환기장치의 실제 초미세먼지 제거 효과 분석 (Experimental Study of Real Ultrafine Particle Removals with a Residential Heat Recovery Ventilator)

6 페이지
기타파일
최초등록일 2025.06.11 최종저작일 2021.08
6P 미리보기
현장 실험을 통한 주거용 열회수 환기장치의 실제 초미세먼지 제거 효과 분석
  • 미리보기

    서지정보

    · 발행기관 : 한국생태환경건축학회
    · 수록지 정보 : KIEAE Journal / 21권 / 4호 / 105 ~ 110페이지
    · 저자명 : 조경주, 조동우

    초록

    Purpose: The number of apartment houses equipped with heat recovery ventilators has increased. With the heat recovery ventilators in their houses, many residents are trying to change their filters into high-performance filters in order to improve indoor air qualities of their houses. If the residents already know the heat recovery ventilators’ performance of removing ultra-fine particles, it will be possible to enjoy indoor air quality that meets the standard without operating air purifiers. Method: A room of a 85㎡ type apartment unit was selected for the field experiments. Considering that the domestic PM2.5 concentration ‘very bad’ standard is 76μg/㎥ or higher, it was assumed that the indoor ultrafine dust concentration was higher than 76μg/m3 for the experiment.
    For this purpose, on a day when the external PM2.5 concentration was 100μg/m3 or higher, external air was brought into the room to raise the indoor PM2.5 concentration to 90μg/m3 or higher, and then experiments with various air change per hours(ACHs)were conducted using a heat recovery ventilator. Result: With a case of air flow rate 0.5ACH, the indoor PM2.5concentration was about 40μg/m3 in a steady state condition, when the average PM2.5 concentration in the outside air was 159μg/m3. In fact, it was difficult to reduce it to the legal concentration value of 35μg/m3 in the experiment condition. The indoor PM2.5 concentration 2 hours after the start of the experiment was 48μg/㎥ for the 0.5ACH condition, about 26μg/㎥ for 1.0ACH condition, about 22μ g/㎥ for 1.5ACH condition, and the legal concentration is 35μg/㎥ or less under all conditions except 0.5ACH.
    recorded.

    영어초록

    Purpose: The number of apartment houses equipped with heat recovery ventilators has increased. With the heat recovery ventilators in their houses, many residents are trying to change their filters into high-performance filters in order to improve indoor air qualities of their houses. If the residents already know the heat recovery ventilators’ performance of removing ultra-fine particles, it will be possible to enjoy indoor air quality that meets the standard without operating air purifiers. Method: A room of a 85㎡ type apartment unit was selected for the field experiments. Considering that the domestic PM2.5 concentration ‘very bad’ standard is 76μg/㎥ or higher, it was assumed that the indoor ultrafine dust concentration was higher than 76μg/m3 for the experiment.
    For this purpose, on a day when the external PM2.5 concentration was 100μg/m3 or higher, external air was brought into the room to raise the indoor PM2.5 concentration to 90μg/m3 or higher, and then experiments with various air change per hours(ACHs)were conducted using a heat recovery ventilator. Result: With a case of air flow rate 0.5ACH, the indoor PM2.5concentration was about 40μg/m3 in a steady state condition, when the average PM2.5 concentration in the outside air was 159μg/m3. In fact, it was difficult to reduce it to the legal concentration value of 35μg/m3 in the experiment condition. The indoor PM2.5 concentration 2 hours after the start of the experiment was 48μg/㎥ for the 0.5ACH condition, about 26μg/㎥ for 1.0ACH condition, about 22μ g/㎥ for 1.5ACH condition, and the legal concentration is 35μg/㎥ or less under all conditions except 0.5ACH.
    recorded.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

“KIEAE Journal”의 다른 논문도 확인해 보세요!

문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 03월 02일 월요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
1:23 오전