ISO 10211 전열해석을 통한 경량목구조의 주요 구조부 단열성능 데이터베이스 구축 (Establishing a Thermal Performance Database for Major Structural Components of Lightweight Wood-frame House through ISO 10211 Heat Transfer Analysis)

8 페이지
기타파일
최초등록일 2025.05.01 최종저작일 2015.04
8P 미리보기
ISO 10211 전열해석을 통한 경량목구조의 주요 구조부 단열성능 데이터베이스 구축
  • 미리보기

    서지정보

    · 발행기관 : 대한건축학회
    · 수록지 정보 : 대한건축학회논문집 / 31권 / 4호 / 239 ~ 246페이지
    · 저자명 : 장향인, 유동철, 안형준, 오향옥, 조대구

    초록

    This study aimed to establish a thermal performance database for various lightweight wood-frame house envelopes in order to increase the accuracy of insulation assessment and energy performance analysis for lightweight wood-frame buildings. The differences in energy and insulation performances were analyzed based on the thermal transmittance calculation method for composite walls. The linear thermal transmittance (Ψ), equivalent thermal transmittance (Ueq), and thermal conductivity of various composite walls for lightweight wood-frame houses were calculated. PHYSIBEL Trisco V.12 was used for the heat transfer analysis, and DesignBuilder V.3.4 was used for the energy performance analysis. The thermal transmittance in the case studies was compared with the heat transfer analysis, and the results confirmed a difference of 3.8%–22.7% for the thermal transmittance and a difference of 3.2%–12.1% for the heating energy. When heat transfer analysis was conducted for various configurations of the lightweight wood-frame house such as the stud spacing, stud thickness, stud placement, and presence of an airtight layer, the results showed a linear thermal transmittance (ψ) difference that was approximately 4.8 times depending on the wall configuration. The thermal conductivity (λ) of the inversion stud and insulation layer was 0.0433–0.0492 W/m·K, indicating a maximum of 11.9% on the stud interval of 406 mm (16 in) and 0.0404–0.0452 W/m·K indicating a maximum of 10.6% on the interval of 610 mm(24 in). With the database established in this study, the thermal performance of the composite walls in lightweight wood-frame houses can be calculated without a complex heat transfer analysis and can be used as basic data for the construction of eco-friendly low-energy wooden structures.

    영어초록

    This study aimed to establish a thermal performance database for various lightweight wood-frame house envelopes in order to increase the accuracy of insulation assessment and energy performance analysis for lightweight wood-frame buildings. The differences in energy and insulation performances were analyzed based on the thermal transmittance calculation method for composite walls. The linear thermal transmittance (Ψ), equivalent thermal transmittance (Ueq), and thermal conductivity of various composite walls for lightweight wood-frame houses were calculated. PHYSIBEL Trisco V.12 was used for the heat transfer analysis, and DesignBuilder V.3.4 was used for the energy performance analysis. The thermal transmittance in the case studies was compared with the heat transfer analysis, and the results confirmed a difference of 3.8%–22.7% for the thermal transmittance and a difference of 3.2%–12.1% for the heating energy. When heat transfer analysis was conducted for various configurations of the lightweight wood-frame house such as the stud spacing, stud thickness, stud placement, and presence of an airtight layer, the results showed a linear thermal transmittance (ψ) difference that was approximately 4.8 times depending on the wall configuration. The thermal conductivity (λ) of the inversion stud and insulation layer was 0.0433–0.0492 W/m·K, indicating a maximum of 11.9% on the stud interval of 406 mm (16 in) and 0.0404–0.0452 W/m·K indicating a maximum of 10.6% on the interval of 610 mm(24 in). With the database established in this study, the thermal performance of the composite walls in lightweight wood-frame houses can be calculated without a complex heat transfer analysis and can be used as basic data for the construction of eco-friendly low-energy wooden structures.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

“대한건축학회논문집”의 다른 논문도 확인해 보세요!

문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
  • EasyAI 무료체험
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2025년 10월 14일 화요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
5:53 오전