녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정 (The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light)

7 페이지
기타파일
최초등록일 2025.03.29 최종저작일 2014.10
7P 미리보기
녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정
  • 미리보기

    서지정보

    · 발행기관 : 대한의용생체공학회
    · 수록지 정보 : 의공학회지 / 35권 / 5호 / 125 ~ 131페이지
    · 저자명 : 장기영, 고현철, 이정직, 윤영로

    초록

    The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two greenlight emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diodeis suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature.
    Another study showed that, green light is better for monitoring heart rate during motion than led light. However,it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensorusing green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambientlight and will propose a solution. This study has two parts of research method. One is measurement system thatcomposed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmographysignal is measured by measurement board that composed high-pass filter, low-pass filter andamplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmographysignal is measured with lead II electrocardiography signal at the same time and it is measuredat the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standardsignal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform.
    The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparingthe correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emittingdiodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambientlight. The waveform and heart rate that measured by two green light emitting diodes are more identical than others.
    The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

    영어초록

    The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two greenlight emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diodeis suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature.
    Another study showed that, green light is better for monitoring heart rate during motion than led light. However,it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensorusing green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambientlight and will propose a solution. This study has two parts of research method. One is measurement system thatcomposed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmographysignal is measured by measurement board that composed high-pass filter, low-pass filter andamplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmographysignal is measured with lead II electrocardiography signal at the same time and it is measuredat the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standardsignal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform.
    The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparingthe correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emittingdiodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambientlight. The waveform and heart rate that measured by two green light emitting diodes are more identical than others.
    The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우
문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 03월 24일 화요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
7:19 오후