열순환 처리한 유동형 복합레진의 물리적 특성
  • 미리보기

    서지정보

    · 발행기관 : 대한치과재료학회
    · 수록지 정보 : 대한치과재료학회지 / 36권 / 2호 / 117 ~ 124페이지
    · 저자명 : 전성민, 이계영, 유미경, 이광원, 배태성

    초록

    This study was performed to evaluate the tensile strength and abrasion by toothbrush of flowable composite resins. Seven commercially available flowable composite resins (FiltekTM Flow, Palpique Estelite LV High Flow, Medium Flow 및 Low Flow, UniFilⓇ Flow, RevolutionTM Formula 2, and Esthet-X Flow) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a split teflon mold giving 5 ㎜ in gauge length and 2 ㎜ in thickness. Wear specimens were fabricated into disc shape with diameter of 15 ㎜ and thickness of 1.5 ㎜ in a split teflon mold. All samples of each material group were stored in deionized water at 37℃±1℃ for 30 days. Thermocycling was conducted for 10,000 times with 15 s holds in each 5℃ and 55℃ water baths. Tensile testing was carried out at a crosshead speed of 0.5 ㎜/min. Toothbrushing was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles.
    The results obtained were summarized as follows;
    1. The highest tensile strength of 81.8 ㎫ was observed in the UF group and lowest value of 45.9 ㎫ was observed in the PL group after aging in deionized water at 37℃±1℃ for 30 days. The result of Tukey test showed the significant differences between UF, EX, and PL groups (P<0.05).
    2. The highest tensile strength of 64.6 ㎫ was observed in the RE group and lowest value of 42.3 ㎫ was observed in the PH group after 10,000 thermocycles, but all strength values showed no significant differences between in each group (P>0.05).
    3. Comparison of the tensile strength values between aging group and thermocycling group showed significant decreases of α=0.01 in the UF group and α=0.05 in the PH and EX groups.
    4. Comparison of arithmetical mean deviation from the mean line, Ra, after thermocycling test showed the highest value of 0.559 in the FT group and lowest value of 0.052 in the PL group. The result of Tukey test showed the significant differences between FT, EX, UF, and PL groups (P<0.05).
    5. SEM observation of abraded surfaces revealed the protrusion and missing of filler particles by the selective removal of matrix resin.

    영어초록

    This study was performed to evaluate the tensile strength and abrasion by toothbrush of flowable composite resins. Seven commercially available flowable composite resins (FiltekTM Flow, Palpique Estelite LV High Flow, Medium Flow 및 Low Flow, UniFilⓇ Flow, RevolutionTM Formula 2, and Esthet-X Flow) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a split teflon mold giving 5 ㎜ in gauge length and 2 ㎜ in thickness. Wear specimens were fabricated into disc shape with diameter of 15 ㎜ and thickness of 1.5 ㎜ in a split teflon mold. All samples of each material group were stored in deionized water at 37℃±1℃ for 30 days. Thermocycling was conducted for 10,000 times with 15 s holds in each 5℃ and 55℃ water baths. Tensile testing was carried out at a crosshead speed of 0.5 ㎜/min. Toothbrushing was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles.
    The results obtained were summarized as follows;
    1. The highest tensile strength of 81.8 ㎫ was observed in the UF group and lowest value of 45.9 ㎫ was observed in the PL group after aging in deionized water at 37℃±1℃ for 30 days. The result of Tukey test showed the significant differences between UF, EX, and PL groups (P<0.05).
    2. The highest tensile strength of 64.6 ㎫ was observed in the RE group and lowest value of 42.3 ㎫ was observed in the PH group after 10,000 thermocycles, but all strength values showed no significant differences between in each group (P>0.05).
    3. Comparison of the tensile strength values between aging group and thermocycling group showed significant decreases of α=0.01 in the UF group and α=0.05 in the PH and EX groups.
    4. Comparison of arithmetical mean deviation from the mean line, Ra, after thermocycling test showed the highest value of 0.559 in the FT group and lowest value of 0.052 in the PL group. The result of Tukey test showed the significant differences between FT, EX, UF, and PL groups (P<0.05).
    5. SEM observation of abraded surfaces revealed the protrusion and missing of filler particles by the selective removal of matrix resin.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우
문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 01월 28일 수요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
2:02 오전