디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과 (Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position)

15 페이지
기타파일
최초등록일 2025.05.23 최종저작일 2009.09
15P 미리보기
디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과
  • 미리보기

    서지정보

    · 발행기관 : 대한영상치의학회
    · 수록지 정보 : Imaging Science in Dentistry / 39권 / 3호 / 133 ~ 147페이지
    · 저자명 : 김미자, 최보람, 허경회, 이원진, 허민석, 이삼선, 최순철

    초록

    Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometry, and to investigate the effect of head position on the measurement during imaging with MDCT.
    Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometry was taken in standard position, and MDCT was taken in standard position and two rotated position (10left rotation and 10right tilting). MDCT data were imported in OnDemand® and lateral cephalometry were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six cephalometries, sixteen angular and eleven linear measurements were made in V-Ceph® three times. Reproducibility of measurements was assessed using repeated measures ANOVA and ICC. Linear and angular measurements were compared between digital cephalometry and five MDCT-synthesized cephalometries by Student t-test.
    Results : All measurements in six types of cephalometry were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized cephalometries (P¤0.05). Measurements in MDCT-synthesized cephalometry in 10left rotation or 10right tilting position showed possibility of difference from digital cephalometry in some measurements, and possibility of improvement via realignment of head position using both ear rods.
    Conclusions : MDCT-synthesized cephalometry can substitute conventional cephalometry. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized cephalometry, and these position error can be corrected by realignment of the head position using both ear rods.

    영어초록

    Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometry, and to investigate the effect of head position on the measurement during imaging with MDCT.
    Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometry was taken in standard position, and MDCT was taken in standard position and two rotated position (10left rotation and 10right tilting). MDCT data were imported in OnDemand® and lateral cephalometry were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six cephalometries, sixteen angular and eleven linear measurements were made in V-Ceph® three times. Reproducibility of measurements was assessed using repeated measures ANOVA and ICC. Linear and angular measurements were compared between digital cephalometry and five MDCT-synthesized cephalometries by Student t-test.
    Results : All measurements in six types of cephalometry were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized cephalometries (P¤0.05). Measurements in MDCT-synthesized cephalometry in 10left rotation or 10right tilting position showed possibility of difference from digital cephalometry in some measurements, and possibility of improvement via realignment of head position using both ear rods.
    Conclusions : MDCT-synthesized cephalometry can substitute conventional cephalometry. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized cephalometry, and these position error can be corrected by realignment of the head position using both ear rods.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

“Imaging Science in Dentistry”의 다른 논문도 확인해 보세요!

문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 02월 04일 수요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
4:52 오후