다중 검출 유도결합 플라즈마 질량분석기를 이용한 납 및 카드뮴안정동위원소비 분석의 질량 편향 보정방법 비교
  • 미리보기

    서지정보

    · 발행기관 : 한국환경분석학회
    · 수록지 정보 : 환경분석과 독성보건 / 17권 / 3호 / 173 ~ 181페이지
    · 저자명 : 김지영, 김명진, 유은진, 이강현, 이경석, 이원석, 최종우, 권오상

    초록

    To obtain precise and accurate isotope ratios with a multi-collector ICP-MS, three methods such as interelementalinternal calibration, sample-standard bracketing (SSB), and log-log linear regression correctionmodel were applied to isotope ratio measurement of lead (Pb) and cadmium (Cd) for the correction of instrumentalmass discrimination. Certified reference materials including NIST SRM 981 (Pb), NIST SRM 3108(Cd), and BAM I012 (Cd) were used as reference materials for the isotope ratios of lead and cadmium to comparethe corrected results obtained from the respective correction models. The accuracies of lead isotope ratiomeasurements were in the range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % when the inter-elementalinternal calibration applied. The same range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % was also found withthe SSB method. The log-log linear regression correction model, on the other hand, showed a differentrange of -2.160 (207/206Pb) to 0.219 (208/204Pb) %. The precisions of lead isotope ratios with these three correctionmethods ranged from 0.027 (206/204Pb) to 0.127 (208/204Pb), 0.025 (206/204Pb) to 0.124 (208/204Pb), and1.265 (207/204Pb) to 1.367 (207/206Pb), respectively. Therefore, both of the inter-elemental internal calibrationand the SSB method were selected as good methods for mass bias correction of lead isotope ratios. Theε114/110Cd values obtained from the application of the three different correction models were -14.5±0.7 (Agas an internal standard), -13.0±2.1 (SSB), and -15.2±1.8 (log-log linear regression correction model),respectively. For ε114/110Cd values, the inter-elemental internal calibration showed the best precisionamong the three correction methods. Isobaric interferences with cadmium were also corrected when correctioncoefficients were applied to each isotope of cadmium. The difference of correction coefficientsbetween the isotope ratios with natural abundances and the empirical ratios in the isobaric interferencesreached up to 11%. The heavier isobaric interferences (106, 108, 110Pd vs.
    105Pd) were underestimated in theapplication of the natural ratios, while the lighter isobaric interferences (112,114,116Sn vs.
    118Sn and113In vs.
    115In) were overestimated. In conclusion, the inter-elemental internal calibration and the SSB method canproperly correct the isotope ratios of interest in the isotope ratio measurement using the MC-ICP-MS.
    Further research on the isotope ratio analysis of environmental samples should follow to improve precisionand accuracy.

    영어초록

    To obtain precise and accurate isotope ratios with a multi-collector ICP-MS, three methods such as interelementalinternal calibration, sample-standard bracketing (SSB), and log-log linear regression correctionmodel were applied to isotope ratio measurement of lead (Pb) and cadmium (Cd) for the correction of instrumentalmass discrimination. Certified reference materials including NIST SRM 981 (Pb), NIST SRM 3108(Cd), and BAM I012 (Cd) were used as reference materials for the isotope ratios of lead and cadmium to comparethe corrected results obtained from the respective correction models. The accuracies of lead isotope ratiomeasurements were in the range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % when the inter-elementalinternal calibration applied. The same range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % was also found withthe SSB method. The log-log linear regression correction model, on the other hand, showed a differentrange of -2.160 (207/206Pb) to 0.219 (208/204Pb) %. The precisions of lead isotope ratios with these three correctionmethods ranged from 0.027 (206/204Pb) to 0.127 (208/204Pb), 0.025 (206/204Pb) to 0.124 (208/204Pb), and1.265 (207/204Pb) to 1.367 (207/206Pb), respectively. Therefore, both of the inter-elemental internal calibrationand the SSB method were selected as good methods for mass bias correction of lead isotope ratios. Theε114/110Cd values obtained from the application of the three different correction models were -14.5±0.7 (Agas an internal standard), -13.0±2.1 (SSB), and -15.2±1.8 (log-log linear regression correction model),respectively. For ε114/110Cd values, the inter-elemental internal calibration showed the best precisionamong the three correction methods. Isobaric interferences with cadmium were also corrected when correctioncoefficients were applied to each isotope of cadmium. The difference of correction coefficientsbetween the isotope ratios with natural abundances and the empirical ratios in the isobaric interferencesreached up to 11%. The heavier isobaric interferences (106, 108, 110Pd vs.
    105Pd) were underestimated in theapplication of the natural ratios, while the lighter isobaric interferences (112,114,116Sn vs.
    118Sn and113In vs.
    115In) were overestimated. In conclusion, the inter-elemental internal calibration and the SSB method canproperly correct the isotope ratios of interest in the isotope ratio measurement using the MC-ICP-MS.
    Further research on the isotope ratio analysis of environmental samples should follow to improve precisionand accuracy.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

“환경분석과 독성보건”의 다른 논문도 확인해 보세요!

문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 02월 02일 월요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
4:04 오전