브릿지 형태의 상부보철물 및 상부보철물의 나사풀림에 따른 타진식 임플란트 안정성 측정기기의 수치비교 (Study of the Differences in a Percussion-type Implant Stability Measuring Instrument according to Bridge prosthesis and screw loosening)

9 페이지
기타파일
최초등록일 2025.06.22 최종저작일 2022.12
9P 미리보기
브릿지 형태의 상부보철물 및 상부보철물의 나사풀림에 따른 타진식 임플란트 안정성 측정기기의 수치비교
  • 미리보기

    서지정보

    · 발행기관 : 대한치과의사협회
    · 수록지 정보 : 대한치과의사협회지 / 61권 / 1호 / 8 ~ 16페이지
    · 저자명 : 권연우, 김철훈, 김복주, 강선우, 김정한, 성현미

    초록

    This study aimed to investigate the effect of different conditions on the implant stability test (IST) value of three-unit implant bridges. Fifteen pairs of specimens were prepared. Two internal conical-type implants were placed in artificial bone using a torque of 35 to 45 Ncm. Three-unit monolithic zirconia bridges (Perfit ZR) were fabricated using CAD-CAM. Im plant Stability Quotient (ISQ) values were measured for each implant. IST value was measured under different conditions: healing abutment, without cementation, with cementation, one prosthesis unscrewed, and two prostheses unscrewed. The results showed statistically significant differences according to the conditions (p <0.05). The lowest IST level was observed in the groups tested on healing abutment and the prosthesis without cementation. The highest IST level was observed in the groups with cemented prostheses. There was no significant difference according to screw loosening. IST values for all groups measured above 79, indicating high stability with consistent tendency. The present study implied that IST values could be used as a reference restrictedly for assessing implant stability and conditions on bridge-type prostheses.

    영어초록

    This study aimed to investigate the effect of different conditions on the implant stability test (IST) value of three-unit implant bridges. Fifteen pairs of specimens were prepared. Two internal conical-type implants were placed in artificial bone using a torque of 35 to 45 Ncm. Three-unit monolithic zirconia bridges (Perfit ZR) were fabricated using CAD-CAM. Im plant Stability Quotient (ISQ) values were measured for each implant. IST value was measured under different conditions: healing abutment, without cementation, with cementation, one prosthesis unscrewed, and two prostheses unscrewed. The results showed statistically significant differences according to the conditions (p <0.05). The lowest IST level was observed in the groups tested on healing abutment and the prosthesis without cementation. The highest IST level was observed in the groups with cemented prostheses. There was no significant difference according to screw loosening. IST values for all groups measured above 79, indicating high stability with consistent tendency. The present study implied that IST values could be used as a reference restrictedly for assessing implant stability and conditions on bridge-type prostheses.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우
문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2026년 01월 22일 목요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
8:40 오전