매설용 전기 발열 매시의 융설 효과에 대한 현장 적용성 연구
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국도로학회
ㆍ수록지정보 : 한국도로학회논문집 / 15권 / 2호
ㆍ저자명 : 서영찬, 서병석, 송중곤, 조남현
ㆍ저자명 : 서영찬, 서병석, 송중곤, 조남현
영어 초록
PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature (0℃) to the reference temperature (5~8℃) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.참고 자료
없음태그
"한국도로학회논문집"의 다른 논문
- 도로 융설체 개발을 위한 탄소나노튜브-시멘트 복합체 특성에 관한 실험적 연구9페이지
- 탄소포집 활성 고로슬래그 모르타르의 기초특성에 관한 연구9페이지
- 한국 도로 자본이 산업에 미친 영향과 생산성 분석13페이지
- 미시적 시뮬레이션을 이용한 중앙버스전용차로 효과분석9페이지
- 편익과 비용 분석을 통한 소형차전용지하차도 도입에 관한 연구9페이지
- 고속도로에서 발생한 2차 교통사고의 특성분석9페이지
- Tobit 모형을 이용한 간선도로 사고 요인 분석8페이지
- 국내 로터리의 연령대별 사고모형9페이지
- 폴리우레탄 바인더를 활용한 친환경 도로포장용 혼합물 개발7페이지
- 도로하부 매설관의 매설심도 및 되메우기 재료가 포장체에 미치는 영향 평가8페이지