it is opened or closed depending on the power input. ... Expansion valve (5) Solenoid valveThe Solenoid valve for main duct controls the refrigerant flow as ... Evaporator (4) Expansion valveThe expansion valve insulates and expands the high temperature and pressure
flow as it is opened or closed depending on the power ... Fig. 9 Expansion valve (5) Solenoid valveThe electronic valve for main duct controls the refrigerant ... SEQ Fig. \* ARABIC 8 Evaporator (4) Expansion valveThe manual expansion valve insulates and expands
Openthe two valves so that the pressure should be same for the two ends. ... Confirm the output value of the differential manometer. 3)Open completely the bypass valve with all valves ... shut-down.) 5)Measure the pressure drop after opening the valves between the test section and differential
(left one) ③ After bubbles are removed completely, close the air vent valve ④ Openthe pressure valve ... manometer ① Close the pressure valve (right one connected with rubber blower) ② Openthe air vent valve ... Experimental Process 1) Release all thevalves ins rate using the bypass valve and the control valve.
Procedures 1) Set up the apparatus, turn on the water supply, and partially openthe discharge valve ... This is to calculate Reynolds number. 5) Slowly increase the flow rate by openingthe discharge valve ... ink valve, glass wool, drip valve, control valve), mess cylinder, stop watch, thermometer 2) Reagents
is always opened to drain the condensate. ... When the economizer is inactive, the condensate drain valve on the soot blower steam inlet pipe line ... In this study, a condensate drain valve was newly installed in the steam inlet pipe line of the soot
the syringe pump with liquid carbon dioxide and openthevalve to supply carbon dioxide to the view ... carbon dioxide to view cell by filling liquid CO2 with Syringe pump and openingvalve. ... bar. ⑤Lower the pressure to atmospheric pressure, then openthe upper lid and clean the interior.
to medium as shown in Test 2 and openthe expansion valve wider. ... Theoretically, when more expansion valves are opened, the pressure and the temperature should be ... Test 4 adjusts the expansion valve, and test 5 varies the fan speed of the evaporator.
Openthe pressure control valve on the CO2 cylinder and adjust valve V1 to provide a value of approximately ... Adjust the water flowing through the column to 6L/min on F1 using valve V10. ... Start the compressor and adjust the control valve V2 to provide approximately 30 L/min of air flow.
Partially openthe discharge valve (5) to let water flow into the glass tube (4). ... Open and adjust the ink injector valve to obtain a fine filament of ink in the flow down the glass tube ... Turn on the water inlet valve to supply water to the water tank (6).
밸브를 돌린다 Turn the hydrant valve to the left ? ... 소화전 문을 연다 Openthe fire hydrant door ? 호스를 빼고 노즐을 잡는다 Aim nozzle and hold the nozzle ? ... 손잡이를 움켜쥔다 Squeeze the handle ?
Partially openthe discharge valve (5) to let water flow into the glass tube (4). ... Open and adjust the ink injector valve to obtain a fine filament of ink in the flow down the glass tube ... Turn on the water inlet valve to supply water to the water tank (6).
Fill syringe pump with liquid CO _{2} and openvalve to supply CO _{2} to view cell. ... Close valve to isolate cell, and increase the temperature. 4. ... Lower pressure to atmospheric pressure, openthe upper lid and clean the inside. Ⅴ inference We will
The first test is to observe the threshold of CO2 SCF and open only thevalve number 1. ... There are three valves, valve 1 supplies CO2, valve 2 is connected to the pump, and valve 3 is a valve ... 첫 번째 실험은 그래프에서 A, B, C의 상 동작을 잘 나타내는 그림을 표시했다. 3개의 밸브가 있는데 밸브1은 CO2를 공급하고, 밸브2는 펌프랑 연결되어있고, 밸브3은 CO2를
equipment (power button and pump button). 2) Open or close the slide valve connected to the water pump ... flow rate and the size of thevalve, thevalve's dog, and the method of joints, and so on, and the loss ... 2) Losses due to fitting and valve In order to control the volume or direction of fluid flow, thevalve
manometer by openingthe vent screw on the top of thevalve and using the air pump. ... in the test column is spilled on the floor or flown into the air. ... Check the initial pressure through the CEL.
One of the two pipes is completely closed using the on/off valve, the other is opened, and the piston ... Open `DataStudio` software on the Desktop 2. ... Choose Open Activity and select the file Heat Engine data.ds 3.
the main power switch and check all gauges. (3) Charge the Feed-tank with 50mol% MeOH 3L and openthe ... V1~V5=valve 1) Apparatus Figure 6. ... feed-tank valve and fill the reboiler 50mol% MeOH 3L. (4) Check the tubes and pipes of the cooling uct
. ⑥ Adjust theopening of the expansion valve, and repeat the ② and ③ with the fan on medium speed. ⑦ ... We repeated the experiment 5times by changing condenser fan speed, expansion valve, evaporator valve. ... Conclusion R-22 용매를 이용하여 condenser 팬 속도, 팽창밸브, evaporator 팬 속도를 조절해가며 냉동사이클 실험을 진행하였다.
intensity of the leakage is adjusted by changing the size of the leak hole and theopening rate of ball ... valve. ... Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise