본문내용
본 연구는 규정 유량, 양정, 회전수 및 비속도가 각각 0.3m/min, 17m, 1750rpm인 원심펌프의 운전 시 펌프의 회전수와 유량의 변화가 펌프의 운전특성에 미치는 영향을 고찰하였다.
실험에 사용된 펌프는 1370rpm에서 100rpm씩 1770rpm까지 5단계의 회전수 변화에 따른 특성, 특성, 특성 등의 관계와 무 차원 성능 특성인 양정계수(Head coefficient), 동력계수(Power coefficient), 효율(Efficient)등의 특성을 실험을 통하여 다음과 같은 결론을 얻었다.
(1) 전압이 205V로 일정하고, 전류가 증가함에 따라 양정은 낮아지고 효율은 높아짐을 알 수 있었다.
(2) 펌프의 최대효율은 1370에서 유량 0.172/ 양정 12.2에서 약 44%의 효율을 나타내며, 펌프의 최대회전수의 1770에서는 유량 0.235/ 양정 19.8에서 약 43%의 효율을 나타낸다.
(3) 동일 회전수에는 유량의 증가에 따라 동력은 증가하고 유량은 증가 초기에 양정은 평탄 특성을 나타낸다.