Development of Bi0.5(Na0.78K0.22)0.5TiO3 Lead-free Piezoelectric Ceramic Material with Core-shell Structure for Biomedical
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국산업경영시스템학회
ㆍ수록지정보 : 산업경영시스템학회지 / 46권 / 3호
ㆍ저자명 : Seong-jun Yun, Joonsoo Bae
ㆍ저자명 : Seong-jun Yun, Joonsoo Bae
목차
1. 서 론2. 실험방법
3. 결과 및 고찰
4. 결 론
Acknowledgments
영어 초록
BNKT Ceramics, one of the representative Pb free based piezoelectric ceramics, constitutes a perovskite(ABO3) structure. At this time, the perovskite structure (ABO3) is in the form where the corners of the octahedrons are connected, and in the unit cell, two ions, A and B, are cations, A ion is located at the body center, B ion is located at each corner, and an anion O is located at the center of each side. Since Bi, Na, and K sources constituting the A site are highly volatile at a sintering temperature of 1100℃ or higher, it is difficult to maintain uniformity of the composition. In order to solve this problem, there should be suppression of volatilization of the A site material or additional compensation of the volatilized. In this study, the basic composition of BNKT Ceramics was set to Bi0.5(Na0.78K0.22)0.5TiO3 (= BNKT), and volatile site (Bi, Na, and K sources) were coated in the form of a shell to compensate additionally for the A site ions. In addition, the physical and electrical properties of BNKT and its coated with shell additives(= @BNK) were compared and analyzed, respectively. As a result of analyzing the crystal structure through XRD, both BNKT(Core) and @BNK(Shell) had perovskite phases, and the crystallinity was almost similar. Although the Curie temperature of the two sintered bodies was almost the same (TC = 290 ~ 300 ℃), it was confirmed that the d33 (piezoelectric coefficient) and Pr (residual polarization) values were different. The experimental results indicated that the additional compensation for a shell additive causes the coarsening, resulting in a decrease in sintering density and Pr(remanent polarization). However, coating shell additives to compensate for A site ion is an effective way to suppress volatilization. Based on these experimental results, it would be the biggest advantage to develop an eco-friendly material (Lead-free) that replaced lead (Pb), which is harmful to the human body. This lead-free piezoelectric material can be applied to a biomedical device or products(ex. earphones (hearing aids), heart rate monitors, ultrasonic vibrators, etc.) and skin beauty improvement products (mask packs for whitening and wrinkle improvement).참고 자료
없음"산업경영시스템학회지"의 다른 논문
- Standardization Research on Drone Image Metadata in the..10페이지
- Development of 2D Data Quality Validation Techniques fo..8페이지
- Development of Deep Learning-based Land Monitoring Web ..10페이지
- Seamline Detection for Image Mosaicking with Image Pyra..7페이지
- A Study on the Using Drone Images in Cadastral Resurvey9페이지
- Exploring Spatio-temporal Patterns of Population and it..8페이지
- The Impact of Project Governance Factors on IT Project ..10페이지
- Analyzing the impact of Consultant and Project Manager ..10페이지
- Analysis of the Effectiveness of Project Risk Managemen..10페이지
- Investigating the Impact of Project Management on Const..12페이지