An Investigation into the Production of Rapid Prototyping of Splint through XR (eXtended Reality)-Based 3D Scanning and Printing
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 국제물리치료학회
ㆍ수록지정보 : Journal of International Academy of Physical Therapy Research / 14권 / 2호
ㆍ저자명 : Myeongtaek Hong, Hyunyoung Lee, Seunghun Jeong, Seonwook Kim, Youmin Kim, Wansuk Choi, PT, Prof., PhD, Seoyoon Heo, OT, ATP, PhD
ㆍ저자명 : Myeongtaek Hong, Hyunyoung Lee, Seunghun Jeong, Seonwook Kim, Youmin Kim, Wansuk Choi, PT, Prof., PhD, Seoyoon Heo, OT, ATP, PhD
목차
INTRODUCTIONMETHODS
Study Design and Sequences
Traditional Orthotic Fabrication Method UtilizingThermoplastic Resin
Methodology for creating assistive devices using3D scanner, commercial CAD software, and 3Dprinting technology
Fabrication Method of Arm Splint Based on XR(eXtended Reality) Algorithm
RESULTS
DISCUSSION
CONCLUSION
영어 초록
Background: This study attempted a comparative analysis of three splint fabrication methods currently used in clinical fields. Traditional Orthotic Fabrication Method Utilizing Thermoplastic Resin, the Methodology for creating assistive devices using 3D scanner, commercial CAD software, and 3D printing technology, and the Fabrication Method of Arm Splint Based on XR (eXtended Reality) Algorithm. Objectives: The study recruited 12 undergraduate students majoring in physical therapy and occupational therapy who had sufficient knowledge of splints, with an equal gender distribution. The study randomized the participants and conducted the experiment and overall process using a stratified approach. Design: Clinical applied technology experiment Methods: The study used QUEST 2.0 (Quebec User Evaluation of Satisfaction with assistive Technology ver. 2.0) to survey standardization, weight, ease of use, safety, durability, usability, effectiveness, and patient satisfaction, and statistically analyzed all results as quantitative indicators. Results: The score of QUEST 2.0 showed different aspects in some items, and it is difficult to say that certain technologies are superior overall. Conclusion: The study attempted an intuitive interpretation of the results. Overall, it was concluded that the XR method, which allows for easy and fast fabrication, is likely to be more readily accepted in future clinical practice.참고 자료
없음"Journal of International Academy of Physical Therapy Research"의 다른 논문
- Effect of Thoracic Vertebra Joint Mobilization on Heart..6페이지
- Application of Robotic Rehabilitation to Patients with ..6페이지
- Effects of Kinesio Taping on Total Knee Arthroplasty Pa..9페이지
- Effect of Frequency-Specific Application of Maitland on..7페이지
- Effects of Pilates Exercise Using Cadillac Equipment on..7페이지