전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2017.08
- 8페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 대한상하수도학회
ㆍ수록지정보 : 상하수도학회지 / 31권 / 4호
ㆍ저자명 : 엄세은, 장인성
영어 초록
Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and 24 A/m2) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, Rt(=Rc+Rf) were calculated and compared to those of the controls (R0), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt / R0) was carried out and the equation i0.46t=7.0 was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.
참고 자료