형광입자를 이용한 분리막 표면 검측 방법의 파일럿 규모 플랜트 적용
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2016.02
- 8페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 대한상하수도학회
ㆍ수록지정보 : 상하수도학회지 / 30권 / 1호
ㆍ저자명 : 김초아, 김희준, 조진우
영어 초록
In this study, a fluorescent silica nano particle is used as the surrogate for challenging test of membrane surface integrity. The particles are functionalized by a fluorescent dying agent so that as an ultraviolet light is imposed a bright fluorescent image from the particles can be taken. If a membrane surface is damaged and has a compromised part larger than the size of surrogate the fluorescent particles would pass through and contained in the permeate. An operator can directly notice whether the membrane surface is damaged or not by detecting a fluorescent image taken from the permeate. Additionally, the size of compromised part is estimated through analysing the fluorescent image in which we surmise the mass of particles included in the permeate by calculating an average RGB value of the image. The pilot scale experiments showed that this method could be applied successfully to determine if a membrane surface had a damaged parts regardless of the test condition. In the testing on the actual damaged area of 4.712 mm2, the lowest error of estimating the damaged area was –1.32% with the surrogate concentration of 80 mg/L, flux of 40 L/m2/hr for 25 minutes of detection. A further study is still going on to increase the lowest detection limit and thus decrease the error of estimation.
참고 자료
없음
"상하수도학회지"의 다른 논문
더보기 (5/10)