무방류 재이용 시스템 현장 적용성 평가
(주)코리아스칼라
- 최초 등록일
- 2016.04.01
- 최종 저작일
- 2011.12
- 7페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 경북대학교 농업생명과학대학
ㆍ수록지정보 : Current Research on Agriculture and Life Sciences / 29권
ㆍ저자명 : 최경숙, 이광야
영어 초록
This study performed field examinations of a zero discharge and reuse system developed by Hong and Choi(2009). The system installed one of villages located in Hyoryeong-myeon, Gunwee-gun for the experiments. The zero discharge and reuse system consists of anoxic, FES (Ferrous Electricity System), Oxic, Cralifier processes for water treatments. The main feature of the system is to remove phosphorous by using Fe-ionizing module within the FES process. The water purification performances of the system were evaluated, while any defects for using the system were investigated through the field monitoring. It was found that the removal capacities of T-P, T-N, and BOD of the system meet the required water quality with outstanding performance from T-P by obtaining the results of over 90 % removal rates. The efficiency of T-P removal rate of the system found to be greatly influenced by whether using an automatic washing system to the Fe-ionizing module and conducting replacement of iron plate within a proper period.
참고 자료
없음
"Current Research on Agriculture and Life Sciences"의 다른 논문
더보기 (4/9)