입주전 신축공동주택의 HCHO, VOCs 및 TVOC 오염농도 실태조사에 관한 연구
(주)코리아스칼라
- 최초 등록일
- 2016.04.01
- 최종 저작일
- 2008.06
- 12페이지/ 어도비 PDF
- 가격 4,300원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국실내환경학회
ㆍ수록지정보 : 한국실내환경학회지 / 5권 / 2호
ㆍ저자명 : 김건우, 박진철
영어 초록
This study aims to present the fundamental strategies for improving the Indoor Air Quality ( IAQ ) in newly unoccupied apartment units. The results of this study can be summarized as follows, The field survey of 160 newly unoccupied units with airtight doors and windows showed that the concentrations of HCHO and TVOC were higher than the standards. The emission rates of HCHO and TVOC were proportional to the height. The small chamber test of pollutant concentration for building materials showed that pollutants were emitted dominantly from the wood furnishings and adhesives.