Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2004.03
- 10페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국방사성폐기물학회
ㆍ수록지정보 : 방사성폐기물학회지 / 2권 / 1호
ㆍ저자명 : Ju-Chan Lee, Kyung-Sik Bang, Ki-Seog Seo, Ho-Dong Kim, Byung-Il Choi, Heung-Young Lee
목차
Abstract I. Introduction II. Description of Dry Storage System III. FLUENT Verification Analysis for Natural Convection IV. Thermal Analysis Modelling V. Results and Discussion VI. Conclusions VII. References
영어 초록
This study presents the thermal analyses of a spent fuel dry storage cask under normal and off-normal conditions. The environmental temperature is assumed to be 15 under the normal condition. The off-normal condition has an environmental temperature of 38 . An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The significant thermal design feature of the storage cask is the air flow path used to remove the decay heat from the spent fuel. Natural circulation of the air inside the cask allows the concrete and fuel cladding temperatures to be maintained below the allowable values. The finite volume computational fluid dynamics code FLUENT was used for the thermal analysis. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal and off-normal conditions.