• 파일시티 이벤트
  • LF몰 이벤트
  • 서울좀비 이벤트
  • 탑툰 이벤트
  • 닥터피엘 이벤트
  • 아이템베이 이벤트
  • 아이템매니아 이벤트

Investigation of Heavy Metal Migration from Food Contact Materials used for Food Delivery Using an Inductively Coupled Plasma–Mass Spectrometer

(주)코리아스칼라
최초 등록일
2023.06.19
최종 저작일
2023.04
9페이지/파일확장자 어도비 PDF
가격 4,000원 할인쿠폰받기
다운로드
장바구니

* 본 문서는 배포용으로 복사 및 편집이 불가합니다.

서지정보

발행기관 : 한국식품위생안전성학회 수록지정보 : 한국식품위생안전성학회지 / 38권 / 2호
저자명 : Chae-Yeon Hwang, Young-Jun Kim

목차

ABSTRACT
Materials and methods
Sample collections
Standards and reagents
Analytical instrument
Preparation of standard solutions
Sample preparation
Method validation
Results and discussion
Method validation
Migration monitoring
Distribution of heavy metal concentrations in FCMs
국문요약
Conflict of interests
ORCID
References

영어 초록

The surge in food delivery systems during the coronavirus 2019 pandemic necessitated this study of heavy metal migration from food contact materials (FCMs). A total of 104 samples of FCMs, comprising 51 polypropylene (PP), 21 polyethylene (PE), and 32 polystyrene (PS) samples of six different types of FCMs (containers, covers, table utensils, cups, pouches, and wrappers) used for food delivery distributed in Korea, were collected and investigated for migration of three heavy metals (Pb, Cd, and As) using inductively coupled plasma–mass spectrometry (ICP-MS) to determine whether they complied with Korea’s Standards and Specifications for Utensils, Containers, and Packages. Acetic acid (4%, v/v) was used as the food simulant, and tests were performed at 100oC (in harsh conditions) for 30 min. Linearity of Pb, Cd, and As showed acceptable results with a coefficient of determination (R2) value of 0.9999. Limit of detection (LOD) and limit of quantification (LOQ) of Pb, Cd, and As were 0.001, 0.001, and 0.001 μg/L and 0.002, 0.003, and 0.003 μg/L, respectively. Accuracy and precision results complied with the criteria presented in the European Commission Joint Research Centre guidelines. The average concentration of Pb, Cd, and As migration detected in a total of 104 samples was 0.009–0.260 μg/L, which was very low compared with the migration specification set in the Standards and Specifications for Utensils, Containers, and Packages. The maximum level of Pb corresponded to 0.23% of the migration limit. There were no samples exceeding the limit. Thus, this study confirmed that the heavy metal contents of FCMs used for delivery food distributed in Korea were safely managed. The data from this study represent an invaluable source for science-based safety management of hazardous heavy metals migrating from FCMs used in the food delivery industry.

참고 자료

없음

자료문의

제휴사는 별도로 자료문의를 받지 않고 있습니다.

판매자 정보

코리아스칼라는 정직과 신뢰를 기반으로 학술단체 발전에 도움을 드리고자 하는 기업입니다. 본 사는 본 사가 자체 개발한 솔루션을 통하여 보다 효율적인 업무 관리 뿐만 아니라, 학술지의 데이터베이스화, ARCHIVE를 돕습니다. 본 사의 One Stop Service를 통해 국제적인 학술단체로 함께 도약 할 수 있다고 믿습니다.

주의사항

저작권 본 학술논문은 (주)코리아스칼라와 각 학회간에 저작권계약이 체결된 것으로 AgentSoft가 제공 하고 있습니다.
본 저작물을 불법적으로 이용시는 법적인 제재가 가해질 수 있습니다.
환불정책

해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.

파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

이런 노하우도 있어요!더보기

최근 본 자료더보기
탑툰 이벤트
Investigation of Heavy Metal Migration from Food Contact Materials used for Food Delivery Using an Inductively Coupled Plasma–Mass Spectrometer
  • 레이어 팝업
  • 레이어 팝업
  • 레이어 팝업
  • 레이어 팝업