Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국식품위생안전성학회
ㆍ수록지정보 : 한국식품위생안전성학회지 / 32권 / 2호
ㆍ저자명 : Mi Hyune Oh, Moo Song Lim, Jeung Young Chai, Eun Jung Kim, Joong Hoon Cho, Chul Joo Lim, Sun Ok Choi
ㆍ저자명 : Mi Hyune Oh, Moo Song Lim, Jeung Young Chai, Eun Jung Kim, Joong Hoon Cho, Chul Joo Lim, Sun Ok Choi
목차
Materials and MethodsChemicals, standard stock solutions, and columns
Samples
Mobile phases
Sample preparation
Analytical instrumentation
Tandem mass spectrometry conditions
Method validation
Results and Discussion
Optimization of the MS/MS conditions
Optimization of the LC conditions
Method validation
Conclusions
Acknowledgement
국문요약
References
한국어 초록
에너지 음료는 카페인을 주성분으로 타우린, 비타민 같은 다른 energy-enhancing 성분을 함유하고 있다. 미국과 유럽에서는 글루쿠로노락톤이 에너지 음료에 첨가될수 있으나, 국내에서 의약품으로는 허가되어 있다. 따라서 식품 첨가물로는 그 사용이 금지 되어 있어, 지속적으로 수입 및 유통 음료에서 시험검사를 하여 규제하고 있다. 현재 분석법으로 사용하는 LC-PDA 법은 복잡한 유도체화 과 정을 거치고, 음료 중에 당류들이 위양성 결과를 나타내 기도 한다. 이런 기존 방법의 단점을 개선하기 위해 HILICESI- MS/MS (hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry) 를 이용한 분석법을 개발하고, 선택성, 직선성, 검출한계, 정량한계, 정밀도, 정확성, 재현성에 대하여 분석법 유효성 검증을 수행했고, AOAC, EURACHEM 가이드라인에 부합되는 결과를 얻었다.영어 초록
A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster EnergyTM sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%- 14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.참고 자료
없음"한국식품위생안전성학회지"의 다른 논문
- 비브리오 패혈증균에 대한 매실 추출물의 항균활성7페이지
- 영양부추에서 이산화염소와 차아염소산나트륨 처리의 식중독세균 저감화 효과9페이지
- 농업환경에 서식하는 파리에서 분리된 E. coli의 병원성 유전자 및 항생제 내성 조사7페이지
- LC-MS/MS를 이용한 농산물 중 카벤다짐 분석6페이지
- 서울시내 시판 식육에서 분리한 Enterococcus faecalis의 항생제 내성 유형, 다중약물..6페이지
- 국내 유통중인 생닭 및 닭가공품에서 병원성 대장균의 분리 및 특성6페이지
- 계절별 다소비식품 중 무기영양원소 함량 평가6페이지
- 즉석 식품에서 니트로사민이 검출되는 요인 분석9페이지
- 전북권내 냉장·냉동식품 유통차량 온도관리 현황7페이지
- 식품첨가물 바르게 알기 연수를 통한 교사들의 인식 전환과 학생들의 인식 개선 효과6페이지