생체용 Ti-Ta-Mo-Zr 합금 개발에 관한 연구
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2016.06
- 7페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국기계기술학회
ㆍ수록지정보 : 한국기계기술학회지 / 18권 / 3호
ㆍ저자명 : 원대희
영어 초록
This study was purposed to develope a titanium alloy with low elastic modulus to be used as dental implant. The new titanium alloy was prepared as titanium alloy by adding Tantalum(Ta), Zirconium(Zr), Molybdenum(Mo) into the Ti-X-Y-Z system alloys. In designing the new titanium alloys, two physical variables bond order (Bo) and d-electron orbit energy level (Md) were varied. Mean bond order ( ) was around 2.818∼2.8784eV, and Mean d-electron orbit energy level ( ) was 2.4541~2.4747eV. In the cases of titanium alloys of T-3M and T-3Z, the XRD analysis showed β phase. On the other hand, the phase of α+ β were observed in the T-6Z and T-8Z alloys. Exhibited the highest hardness value to result in T-3Z 309.7Hv alloy Vickers hardness with respect to titanium alloy. In the resulting T-3Z alloy of measuring the elastic modulus value for a titanium alloy exhibited the smallest modulus of elasticity value to 89.81GPa. TEM analysis identified additional feature for T-3Z alloy was detected in addition to the ß-phase.
참고 자료
없음
"한국기계기술학회지"의 다른 논문
더보기 (5/10)