비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2016.02
- 11페이지/ 어도비 PDF
- 가격 4,200원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 대한상하수도학회
ㆍ수록지정보 : 상하수도학회지 / 30권 / 1호
ㆍ저자명 : 이용수, 도시현, 홍성호
영어 초록
First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity (qmax) of Fe-GAC for As(V) was 3.49 mg g-1, which was higher than GAC (2.24 mg g-1). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.
참고 자료
없음
"상하수도학회지"의 다른 논문
더보기 (5/10)