A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2005.03
- 8페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국방사성폐기물학회
ㆍ수록지정보 : 방사성폐기물학회지 / 3권 / 1호
ㆍ저자명 : Byong-Ryol Kim, Seung-Chul Park, Byoung-Chul Park, Hyun-Jun Cho, Hyoung-Mo Oh, Tae-Won Hwang, Sang-Woon Shin
목차
ABSTRACT I. 서론 II. 실험 가. 실험방법 나. 전산모사 및 실증시험 평가항목 III. 결과 및 고찰 가. 전산모사 분석결과 나. 실증실험 분석결과 IV. 결론 참고문헌
영어 초록
To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.
참고 자료
없음
"방사성폐기물학회지"의 다른 논문
더보기 (4/9)