• LF몰 이벤트
  • 파일시티 이벤트
  • 서울좀비 이벤트
  • 탑툰 이벤트
  • 닥터피엘 이벤트
  • 아이템베이 이벤트
  • 아이템매니아 이벤트

Comparison of Higher-Order Aberrations and Visual Quality in Eyes Wearing Aspheric and Spherical Silicone Hydrogel Contact Lenses

(주)코리아스칼라
최초 등록일
2016.05.03
최종 저작일
2015.09
12페이지/파일확장자 어도비 PDF
가격 4,300원 할인쿠폰받기
다운로드
장바구니

* 본 문서는 배포용으로 복사 및 편집이 불가합니다.

서지정보

발행기관 : 대한시과학회 수록지정보 : 대한시과학회지 / 17권 / 3호
저자명 : Jeong-Mee Kim, Koon-Ja Lee

목차

Ⅰ. Introduction
Ⅱ. Methods
1. Subjects
2. Contact Lenses
3. Visual Acuity (VA)
4. Contrast Sensitivity (CS)
5. Wavefront higher-order aberrations(HOAs)
6. Pupillometry
7. Experimental procedure
8. Statistical analysis
Ⅲ. Results
1. Assessment of contact lens fit
2. Subjects
3. Visual Acuity
4. Contrast Sensitivity
5. Ocular higher-order aberrations
Ⅳ. Discussion
Ⅴ. Conclusions
References

한국어 초록

목 적: 비구면과 구면 실리콘하이드로겔 콘택트렌즈를 착용시킨 후 고위수차와 시력의 질을 비교 평가 하였다.
방 법: 근시안 25명(나이: 24.32±2.87세)을 대상으로 Biofinity 비구면 실리콘하이드로겔 렌즈와 Acuvue Oasys 구면 실리콘하이드로겔 렌즈를 각각 착용시킨 후, 밝은 조명 (photopic)과 어두운(mesopic) 조명 상태에서, 고대비 및 저대비 시력검사와 3, 6, 12, 18의 공간주파수를 포함하는 대비감도검사를 시행하 였다. 파면수차 분석기를 이용하여 4 mm와 6 mm의 동공 크기에 따른 눈의 고위수차를 렌즈 착용 전과 렌즈 착용 상태에서 각각 측정하였고, 이틀 동안 하루에 한 종류의 렌즈를 착용하였으며 모든 검사는 단안으로 이루어졌다.
결 과: 밝은 조명과 어두운 조명 상태에서 검사한 고대비시력과 저대비시력은 비구면렌즈와 구면렌즈 사이에서 통계적으로 유의한 차이가 없었다. 대비감도는 어두운 조명 상태의 공간 주파수 12cpd에서 두 렌즈 디자인 사이에 유의한 차이가 보였지만(p=0.012), 다른 공간주파수 에서는 조명 상태에 상관없이 유의한 차이가 없었다. 두 종류의 렌즈를 착용한 후 각각의 고위수차 양은 4 mm와 6 mm 동공크기 모두에서 렌즈 착용 전의 고위수차 양를 감소시킨 것으로 나타났으며, 두 렌즈 디자인 사이에서 구면수차만 통계적으로 유의 한 차이가 있었고(4 mm 동공에서 p=0.002; 6 mm 동공에서 p=0.001), 다른 고위수차들은 동공크기에 관계없이 유의한 차이가 없었다.
결 론: 비구면 디자인의 실리콘하이드로겔 콘택트렌즈는 구면 실리콘하이드로겔 렌즈와 비교하여 임상적으로 시력의 질은 차이가 없는 것으로 나타났다.

영어 초록

Purpose: To investigate ocular higher-order aberrations (HOAs) and visual quality when wearing aspheric and spherical silicone hydrogel contact lenses.
Methods: Fifty eyes of 25 myopic subjects (24.32±2.87 years; 13 females, 12 males) participated in this study. Each eye was fitted with two silicone hydrogel lenses of the following brands: Biofinity (aspheric design) and Acuvue Oasys (spherical design). Best-corrected visual acuity (VA) with high and low contrast and best-corrected contrast sensitivity (CS) at 3, 6, 12 and 18 cycles per degree (cpd) were measured under photopic and mesopic conditions. A wavefront analyzer was used to measure ocular HOAs for 4-mm and 6-mm pupils in each eye without and with the contact lenses. All measurements were conducted monocularly by having each subject to wear one lens design per one day during two days.
Results: No statistically significant differences in high contrast or low contrast visual acuity (HCVA or LCVA) were found between the two lens designs under photopic and mesopic conditions. There were no significant differences in CS under photopic or mesopic conditions at other spatial frequencies, although CS under the mesopic conditions at 12 cpd was statistically significant difference between the two lens designs (p=0.012). For ocular HOAs, the level of all HOAs with 4-mm and 6-mm pupils was reduced by two lens designs compared to wearing no lens. Also, there was statistically significant difference in spherical aberration (SA) between the two lens designs within the brands with both pupil sizes (p=0.002, p=0.001, respectively); however, there were no significant differences in any other ocular HOAs between the two lens types with 4-mm or 6-mm pupils.
Conclusion: Aspheric silicone hydrogel contact lenses are not clinically different in visual quality compared with spherical silicone hydrogel contact lenses.

참고 자료

없음

자료문의

제휴사는 별도로 자료문의를 받지 않고 있습니다.

판매자 정보

코리아스칼라는 정직과 신뢰를 기반으로 학술단체 발전에 도움을 드리고자 하는 기업입니다. 본 사는 본 사가 자체 개발한 솔루션을 통하여 보다 효율적인 업무 관리 뿐만 아니라, 학술지의 데이터베이스화, ARCHIVE를 돕습니다. 본 사의 One Stop Service를 통해 국제적인 학술단체로 함께 도약 할 수 있다고 믿습니다.

주의사항

저작권 본 학술논문은 (주)코리아스칼라와 각 학회간에 저작권계약이 체결된 것으로 AgentSoft가 제공 하고 있습니다.
본 저작물을 불법적으로 이용시는 법적인 제재가 가해질 수 있습니다.
환불정책

해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.

파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

이런 노하우도 있어요!더보기

최근 본 자료더보기
탑툰 이벤트
Comparison of Higher-Order Aberrations and Visual Quality in Eyes Wearing Aspheric and Spherical Silicone Hydrogel Contact Lenses
  • 레이어 팝업
  • 레이어 팝업
  • 레이어 팝업
  • 레이어 팝업
  • 레이어 팝업