실내공기 중 휘발성유기화합물 측정의 불확도 평가
(주)코리아스칼라
- 최초 등록일
- 2016.04.01
- 최종 저작일
- 2006.09
- 13페이지/ 어도비 PDF
- 가격 4,500원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국실내환경학회
ㆍ수록지정보 : 한국실내환경학회지 / 3권 / 3호
ㆍ저자명 : 민유선, 유연미, 이승민, 성민기, 허귀석
영어 초록
Uncertainty evaluation was performed for the measurement of Volatile Organic Compounds(VOC) in indoor air. The analytical procedure and result were validated by evaluating every uncertainty source related to the measurement method. An easy approach for uncertainty evaluation for indoor VOC measurement was tested using relative standard uncertainty method which is simple in the evaluation of a measurement uncertainty in case of indoor VOC measurement. The measurement uncertainties of toluene, ethylbenzene, m+p-xylene, styrene and o-xylene in indoor air are obtained as less than or close to 10%, and those results were validated by using Gum-workbench uncertainty evaluation program. Based on the evaluation, uncertainties were found to come largely from two major sources, uncertainty related to the concentration of standard Tenax tube which was used for calibration in measurement, and the to air sampling process. This study could be used as a good example in evaluating uncertainties in the measurement of indoor-air VOC at buildings including a newly-built apartment.
참고 자료
없음
"한국실내환경학회지"의 다른 논문